RF Probe
Model 120 (75 to 110 GHz )
Model 120 (75 to 110 GHz / WR-10 waveguide input) 
  • Parameter
  • Download


High Performance Microwave Probes

Model 120

Features

  • Durable 75 GHz to 110 GHz
  • Insertion loss 1.75 db max (75 to 110 GHz)
  • Return loss 15 db max (75 to 110 GHz)
  • Individually spring loaded contacts
  • Measurement repeatability -50 db
  • Bias T option available
  • Patented coaxial design




undefined
FIGURE 1

The MODEL 120 PICOPROBE? sets new standards in microwave probing performance. Benefiting from coaxial techniques, which have inherent low loss and low dispersion characteristics, the Model 120 Picoprobe?, achieves an insertion loss of less than 1.75 db (typical) and a return loss of greater than 15 db (max.) over its frequency range.

With its individually spring loaded, Beryllium-Copper tips, the Model 120 Picoprobe? provides reliable contacts, even when probing non-planar structures. This reliable low resistance contact is one of the keys to providing highly repeatable measurements (-50 db) at W band frequencies. The Model 120 Picoprobe also provides direct viewing of the probe tips for accurate positioning.

Any pitch (tip spacing) from 50 microns to 450 may be specified. The probe can be configured with Ground-Signal-Ground (G,S,G), Ground-Signal (G,S), or Signal-Ground (S,G) tip footprints. We recommend smaller pitches with a G,S,G footprint for best performance.




120btl
left: Typical uncalibrated performance of a Model 120-GSG-150-BT while touching a 50 Ohm load on our CS-5 Calibration Substrate.
120btr
left: Typical insertion loss of a Model 120-GSG-150-BT.
120bloss
left: The Picoprobe? Model 120's Bias T provides a direct low resistance DC path for supplying up to 1.5 A to a device under test. The Bias T has special circuits which add loss at frequencies below the cut-off frequency (59.05 GHz) of WR-10 waveguide. This data was taken by launching a 40 MHz to 67 GHz signal from the tips of a calibrated Model 67A into the tips of a Model 120-GSG-150-BT. Without this low frequency loss, most active devices will oscillate.
120smith

left: Forward reflection of a Model 120 into an open ended 50 ps coplanar line after an LRM/TRM calibration was performed using our

CS-5 Calibration Substrate. The smooth inwardly spiraling line shows the increasing loss of the 50 ps coplanar line with frequency, coupled with a smoothly changing phase. The CS-5 Calibration Substrate will also perform excellent LRL/TRL and SOLT W-band calibrations. More data is available on request.

FIGURE 2

Micropositioners are available to hold Wiltron V band modules so that the module and the probe are micropositioned as a unit. In this way, total ease of positioning can be achieved with minimum insertion loss.
The probes also have a 3 hole mounting adaptor which will fit standard microwave probe stations. In this case, a longer section of waveguide may be desired to add positioning flexibility.
undefined
FIGURE 3
120lit6 (1)
Model 120-BT Waveguide Dimensions


Model 120-BT-M Waveguide Dimensions

FIGURE 4




Recommended Products
主站蜘蛛池模板: 日韩天码 | 成人在线免费观看视频网站 | 国产a一级毛片 | 91久久精品夜夜躁日日躁欧美 | 精品久久久久久久人人人人传媒 | 涩涩伊人 | 亚洲第一无码av无码专区 | 欧美精品一二区 | 国产精品久久久久久一区二区三区 | 一区二区三区高清在线 | 日韩免费视频中文字幕 | 国产a一级无码毛片一区二区三区 | 国产一级毛片视频 | 久久国产视频播放 | 欧美77 | 思思99精品视频在线观看 | 中文字幕国内一区二区三区 | 成人内射国产免费观看 | 自拍偷拍专区 | 狠狠色婷婷j丁香综合社区 欧美激情精品久久久久久黑人 | 日本aⅴ中文字幕 | 精品一区二区三区久久久 | 青草国产精品久久久久久 | 国产在线欧美日韩精品一区二区 | 国产区精品福利在线社区 | ccyy草草影院地址入口 | 久久精品99av高久久精品 | 亚州av免费 | 国产成人精品a视频 | 日韩插啊免费视频在线观看 | AV网站最新在线观看 | 国产精品毛片久久久久久 | 日韩一二三区视频 | 亚洲高清资源在线观看 | 欧美日韩综合精品码视频 | 希岛爱理av一区二区三区 | 好男人社区官网www 久久免费视频9 | 日韩中文字幕一区二区 | 国产手机精品一区二区 | 国产一区二区在线免费 | 国产网红主播精品一区 |